ANALYSEUR DE BIOCHIMIE BS-300
Random access, fully automated. 300 tests per hour, up to 480 tests per hour with ISE. Up to 50 on-board chemistries. 3 independent probes. Wave length: 340-700nm. Automatic probe cleaning, liquid level detection & collision protection. Automatic sample dilution. Refrigerated reagent compartment. Internal bar code reader. LIS interface bi-directional. Low carry over.
Référence : ???
État : Neuf
System function:
Automatic, Discrete, Random Access.
STAT sample priority.
Throughput: 300 tests/hour, up to 480 tests/hour with ISE. Measuring principles: Absorbance photometry, Turbidimetry. Methodology:
End-point, Initial rate, Kinetic.
Single/Dual reagent chemistries, monochromatic / bichromatic.
Linear / non-linear multipoint calibration.
Programming: User defined profiles and calculation chemistries.
Sample Handling: Sample tray: 60 positions for primary or secondary tubes. Sample volume: 3~45ul, step by 0.5ul. Sample probe: liquid level detection and collision protection. Probe cleaning:
automatic washing for both inside and outside.
carry over < 0.1%.
Automatic sample dilution:
pre-dilution and post-dilution.
dilution ratio up to 150.
dilution vessel: cuvette
Internal bar code reader:
Used for sample programming.
Be applicable to various bar code systems of code 128, code 39, code 93, codabar, ITF, UPC/EAN.
Capable to link with LIS bi-directional.
ISE Module:
Optional selection for K, Na, Cl or K, Na, Cl, Li.
Throughput: Up to 180 or 240 tests per hour.
Reagent Handling:
Reagent Handling:
Reagent tray: 50 positions in refrigerated compartment (4~10?).
Reagent volume: 30~450ul, step by 1ul.
Reagent probe:
liquid level detection and collision protection.
reagent pre-heat and inventory checking.
Probe cleaning:
automatic washing for both inside or outside.
carry over < 0.1%.
Reaction System:
Reaction rotor: rotating tray, 80 cuvettes with automatic loading. Cuvette: optical length 5mm. Reaction volume: 180~500ul. Operating temperature: 37?. Temperature regulation: ± 0.1?. Independent mixing probe.
Optical System: Light Source: Halogen-tungsten lamp. Photometer: reversed optics, static fiber spot photometry. Wavelength: 340, 405, 450, 510, 546, 578, 630, 670, 700nm. Absorption range: -0.5~4.5Abs (10mm conversion). Resolution: 0.001Abs.
Control and Calibration: Calibration mode: linear (one point, two points and multi-points), Logit-Log 4P, Logit-Log 5P, spline exponentialpolynomial parabola. Control software: X-R, L-J, Westguard multi-rule, Cumulative sum check, twin plot.
Operation Unit: Operation system: Windows 2000 Professional. Interface: RS-232.
Working Conditions: Power Supply: AC220V±10%, 50Hz, 1000W (AC110V optional). Temperature: 15-30?. Humidity: 40-80%. Water consumption: 3.5L/hour De-ionized. Dimension: 980mm×710mm×1190mm (W×D×H). Weight: 175kg.